Download The current location: Home > Catalogue and Brochure > ultra high pressure and temperature spinning drop interfacial tensiometer TX500HP

ultra high pressure and temperature spinning drop interfacial tensiometer TX500HP

Number of hits:10324    Release time:2015-04-23

Ultra high pressure and temperature spinning drop interfacial tensiometer model TX500HP is special designed for measurement of interface tension (IFT) between liquid-gas/liquid-fluid system under high pressure and high temperature. Max pressure can reach to 70MPa and temperature range is between -30-200. IFT measurement via pressure and temperature is very useful for application such as Enhanced Oil Recovery (tertiary oil recover). TX500HP can be used to measure IFT between ASP or binary liquid mixture systems and crude oil in the simulated condition with high pressure and temperature with min value about 107mN/m. And beyond that, it can be used to measure IFT of your system with compressed liquid gas such as CO2 or natural gas with extra connector port for gas system.Ultra high pressure and temperature spinning drop interfacial tensiometer model TX500HP is special designed for measurement of interface tension (IFT) between liquid-gas/liquid-fluid system under high pressure and high temperature. Max pressure can reach to 70MPa and temperature range is between -30-200℃. IFT measurement via pressure and temperature is very useful for application such as Enhanced Oil Recovery (tertiary oil recover). TX500HP can be used to measure IFT between ASP or binary liquid mixture systems and crude oil in the simulated condition with high pressure and temperature with min value about 10-7mN/m. And beyond that, it can be used to measure IFT of your system with compressed liquid gas such as CO2 or natural gas with extra connector port for gas system.

ultra high pressure and temperature spinning drop interfacial tensiometry


Hot keywords of USA KINO:contact anglecontact angle measurement,  contact angle meter,  contact angle goniometer,  surface tensiometer, interfacial tensiometer,  surface tension measurement,  surface tension, surface tensiometry, contact angle measurement equipment and device, calculating surfac free energy, Determining Critical Micelle Concentration (CMC) of surfactant, made in China Method for choosing surface tensiometer NEW Method for choosing contact angle meter (goniometer) NEW Method for choosing interfacial tension meter NEW

Manage  technical support: www.chem17.com   GoogleSitemap

MainPro : contact angle,contact angle meter,contact angle goniometer,surface tension,surface tensiometer

Copyright © 2020 KINO Scientific Instrument Inc.  ICP:
Telephone
  • +1 (857) 626-5666